Parameter-Documentation


{'id': 12, 'name': 'tidee', 'num_parameter': 2, 'size_bytes': 4}
Version 00

ERS-1 (Phase A) | SGDR/REAPER | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-1 (Phase B) | SGDR/REAPER | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-1 (Phase B) | SGDR/REAPER | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-1 (Phase C) | SGDR/REAPER | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-1 (Phase C) | SGDR/REAPER | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-1 (Phase D) | SGDR/REAPER | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
2 2 -3 m ptide Pole Tide Correction

ERS-1 (Phase D) | SGDR/REAPER | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-1 (Phase E) | SGDR/REAPER | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-1 (Phase E) | SGDR/REAPER | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-1 (Phase F) | SGDR/REAPER | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-1 (Phase F) | SGDR/REAPER | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-1 (Phase G) | SGDR/REAPER | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-1 (Phase G) | SGDR/REAPER | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-2 | SGDR/REAPER | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

ERS-2 | SGDR/REAPER | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
The permanent tide (zero frequency) is not included. See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See REAPER User Handbook.
Source: SGDR/REAPER
Original-Parameter: pole_tide

Envisat | SGDR v2.1 | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Source: SGDR v2.1
Original-Parameter: solid_earth_tide_ht (Field number 106)
2 2 -3 m ptide Pole Tide Correction
Source: SGDR v2.1
Original-Parameter: geocen_pole_tide_ht (Field number 107)

Envisat | SGDR v2.1 | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Source: SGDR v2.1
Original-Parameter: solid_earth_tide_ht (Field number 106)
2 2 -3 m ptide Pole Tide Correction
Source: SGDR v2.1
Original-Parameter: geocen_pole_tide_ht (Field number 107)

Jason-2 | SGDR-D | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Source: SGDR-D
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
Source: SGDR-D
Original-Parameter: pole_tide

Jason-2 | SGDR-D | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Source: SGDR-D
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
Source: SGDR-D
Original-Parameter: pole_tide

Jason-3 (Extended Mission) | SGDR-F | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Calculated using Cartwright and Tayler tables and consisting of the second and third degree constituents. The permanent tide (zero frequency) is not included. See Jason-3 User Handbook
Source: SGDR-F
Original-Parameter: data_01/solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See Jason-3 User Handbook
Source: SGDR-F
Original-Parameter: data_01/pole_tide

Jason-3 (Extended Mission) | SGDR-F | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Calculated using Cartwright and Tayler tables and consisting of the second and third degree constituents. The permanent tide (zero frequency) is not included. See Jason-3 User Handbook
Source: SGDR-F
Original-Parameter: data_01/solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See Jason-3 User Handbook
Source: SGDR-F
Original-Parameter: data_01/pole_tide

Jason-3 | SGDR-D | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Source: SGDR-D
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
Source: SGDR-D
Original-Parameter: pole_tide

Jason-3 | SGDR-D | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Source: SGDR-D
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
Source: SGDR-D
Original-Parameter: pole_tide

Jason-3 | SGDR-F | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Calculated using Cartwright and Tayler tables and consisting of the second and third degree constituents. The permanent tide (zero frequency) is not included. See Jason-3 User Handbook
Source: SGDR-F
Original-Parameter: data_01/solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See Jason-3 User Handbook
Source: SGDR-F
Original-Parameter: data_01/pole_tide

Jason-3 | SGDR-F | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Calculated using Cartwright and Tayler tables and consisting of the second and third degree constituents. The permanent tide (zero frequency) is not included. See Jason-3 User Handbook
Source: SGDR-F
Original-Parameter: data_01/solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
See Jason-3 User Handbook
Source: SGDR-F
Original-Parameter: data_01/pole_tide

Topex (Extended Mission) | GDR-F | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Calculated using Cartwright and Tayler tables and consisting of the second and third degree constituents. The permanent tide (zero frequency) is not included. See TOPEX User Handbook.
Source: GDR-F
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
Adopts Ries and Desai [2017] model for mean pole location. Xp = 55.0 + 1.677*DT, Yp = 320.5 + 3.460*DT in milliarcseconds with DT = years since 2000.0.
Source: GDR-F
Original-Parameter: pole_tide

Topex (Extended Mission) | GDR-F | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Calculated using Cartwright and Tayler tables and consisting of the second and third degree constituents. The permanent tide (zero frequency) is not included. See TOPEX User Handbook.
Source: GDR-F
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
Adopts Ries and Desai [2017] model for mean pole location. Xp = 55.0 + 1.677*DT, Yp = 320.5 + 3.460*DT in milliarcseconds with DT = years since 2000.0.
Source: GDR-F
Original-Parameter: pole_tide

Topex | GDR | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
2 2 -3 m ptide Pole Tide Correction

Topex | GDR-F | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Calculated using Cartwright and Tayler tables and consisting of the second and third degree constituents. The permanent tide (zero frequency) is not included. See TOPEX User Handbook.
Source: GDR-F
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
Adopts Ries and Desai [2017] model for mean pole location. Xp = 55.0 + 1.677*DT, Yp = 320.5 + 3.460*DT in milliarcseconds with DT = years since 2000.0.
Source: GDR-F
Original-Parameter: pole_tide

Topex | GDR-F | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Calculated using Cartwright and Tayler tables and consisting of the second and third degree constituents. The permanent tide (zero frequency) is not included. See TOPEX User Handbook.
Source: GDR-F
Original-Parameter: solid_earth_tide
2 2 -3 m ptide Pole Tide Correction
Adopts Ries and Desai [2017] model for mean pole location. Xp = 55.0 + 1.677*DT, Yp = 320.5 + 3.460*DT in milliarcseconds with DT = years since 2000.0.
Source: GDR-F
Original-Parameter: pole_tide
Version 01

All Missions

Pos Size Scaling Unit Parameter Description
1 2 -3 m etide Solid Earth Tide Correction
Solid Earth Tide Correction using IERS Convention 2010
Reference:
IERS Conventions (2010). Gérard Petit and Brian Luzum (eds.). (IERS Technical Note ; 36) Frankfurt am Main: Verlag des Bundesamts für Kartographie und Geodäsie, 2010. 179 pp., ISBN 3-89888-989-6
2 2 -3 m ptide Pole Tide Correction
Pole Tide Correction using IERS Convention 2010

Find more topics on the central web site of the Technical University of Munich: www.tum.de