Parameter-Documentation


{'id': 1, 'name': 'agc', 'num_parameter': 2, 'size_bytes': 4}
Version 00

Envisat | SGDR v2.1 | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -2 db agc Automatic Gain Control
Ku band net instrumental correction for AGC
Source: SGDR v2.1
Original-Parameter: ku_net_instr_corr_agc (Field number 86)
2 +2 -2 db agc_rms RMS of AGC

Jason-2 | SGDR-D | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -2 db agc Automatic Gain Control
Ku band corrected AGC
Source: SGDR-D
Original-Parameter: agc_ku
2 +2 -2 db agc_rms RMS of AGC
RMS of the Ku band AGC
Source: SGDR-D
Original-Parameter: agc_rms_ku

Jason-3 (Extended Mission) | SGDR-F | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -2 db agc Automatic Gain Control
Named agc_ku in GDR-D standard. AGC is corrected for instrumental errors due to the imperfections of the on-board attenuators
Source: SGDR-F
Original-Parameter: data_01/ku/agc
2 +2 -2 db agc_rms RMS of AGC
Named agc_rms_ku in GDR-D standard. Compression of Ku band high rate elements is preceded by a detection of outliers. Only valid high-rate values are used to compute this element
Source: SGDR-F
Original-Parameter: data_01/ku/agc_rms

Jason-3 (Extended Mission) | SGDR-F | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -2 db agc Automatic Gain Control
Named agc_ku in GDR-D standard. AGC is corrected for instrumental errors due to the imperfections of the on-board attenuators
Source: SGDR-F
Original-Parameter: data_01/ku/agc
2 +2 -2 db agc_rms RMS of AGC
Named agc_ku in GDR-D standard. AGC is corrected for instrumental errors due to the imperfections of the on-board attenuators
Source: SGDR-F
Original-Parameter: data_01/ku/agc

Jason-3 | SGDR-D | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -2 db agc Automatic Gain Control
Ku band corrected AGC
Source: SGDR-D
Original-Parameter: agc_ku
2 +2 -2 db agc_rms RMS of AGC
RMS of the Ku band AGC
Source: SGDR-D
Original-Parameter: agc_rms_ku

Jason-3 | SGDR-F | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -2 db agc Automatic Gain Control
Source: SGDR-F
Original-Parameter: data_01/ku/agc
2 +2 -2 db agc_rms RMS of AGC
Source: SGDR-F
Original-Parameter: data_01/ku/agc_rms

Jason-3 | SGDR-F | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -2 db agc Automatic Gain Control
Named agc_ku in GDR-D standard. AGC is corrected for instrumental errors due to the imperfections of the on-board attenuators
Source: SGDR-F
Original-Parameter: data_01/ku/agc
2 +2 -2 db agc_rms RMS of AGC
Named agc_rms_ku in GDR-D standard. Compression of Ku band high rate elements is preceded by a detection of outliers. Only valid high-rate values are used to compute this element
Source: SGDR-F
Original-Parameter: data_01/ku/agc_rms

Topex (Extended Mission) | GDR-F | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -2 db agc Automatic Gain Control
1 Hz Ku-band On-Board Attenuator Gain Control (AGC) as provided in the original SDR, which includes temperature corrections.
Source: GDR-F
Original-Parameter: agc_ku
2 +2 -2 db agc_rms RMS of AGC
RMS of 20 Hz Ku-band AGC measurements. Only valid 20 Hz measurements are used to compute this element.
Source: GDR-F
Original-Parameter: agc_rms_ku

Topex (Extended Mission) | GDR-F | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -2 db agc Automatic Gain Control
20 Hz Ku-band On-Board Attenuator Gain Control (AGC) as provided in the original SDR, which includes temperature corrections.
Source: GDR-F
Original-Parameter: agc_20hz_ku
2 +2 -2 db agc_rms RMS of AGC
RMS of 20 Hz Ku-band AGC measurements. Only valid 20 Hz measurements are used to compute this element.
Source: GDR-F
Original-Parameter: agc_rms_ku

Topex | GDR-F | 1Hz

Pos Size Scaling Unit Parameter Description
1 2 -2 db agc Automatic Gain Control
1 Hz Ku-band On-Board Attenuator Gain Control (AGC) as provided in the original SDR, which includes temperature corrections.
Source: GDR-F
Original-Parameter: agc_ku
2 +2 -2 db agc_rms RMS of AGC
RMS of 20 Hz Ku-band AGC measurements. Only valid 20 Hz measurements are used to compute this element.
Source: GDR-F
Original-Parameter: agc_rms_ku

Topex | GDR-F | 20Hz

Pos Size Scaling Unit Parameter Description
1 2 -2 db agc Automatic Gain Control
20 Hz Ku-band On-Board Attenuator Gain Control (AGC) as provided in the original SDR, which includes temperature corrections.
Source: GDR-F
Original-Parameter: agc_20hz_ku
2 +2 -2 db agc_rms RMS of AGC
RMS of 20 Hz Ku-band AGC measurements. Only valid 20 Hz measurements are used to compute this element.
Source: GDR-F
Original-Parameter: agc_rms_ku

Find more topics on the central web site of the Technical University of Munich: www.tum.de